SERIAL COMMUNICATION PROTOCOL
SERIAL COMMUNICATION PROTOCOL
Command Description Response
ACP:a,b||c Congure Auto CUE/PFL Buttons
ACK:
A = Channel number.
1 = Guest CUE/PFL
2 = Monitor CUE/PFL
3 = Presenter CUE/PFL
4 = Reserved
5 = Split CUE/PFL
B = Button Control
1 = on
0 = o
C = Lock Out Button
1 = Lock out
0 = Normal Operation
ACP:a? Read Auto CUE / PFL Button Status ACP:a,b,c
AUX:a,b,||c,d Congure Auxiliary Buttons ACK:
A = Aux Channel number.
1 selects Ch 1
2 selects Ch 2
B = Button Control
1 = on
0 = o
C = Lock Out Button
1 = Lock out
0 = Normal Operation
D = Lock Btn if set to Post when Fader is Up
1 = Lock
0 = Normal Operation
AUX:a? Read Auxiliary Button Status AUX:a,b,c,d
A = Channel number. (see above)
Bnn: Baud Rate ACK: (at old rate)
Nn=11 (115200)
Nn=57 (57600)
Nn=38 (38400)
Nn=19 (19200)
Nn=96 (9600)
BSV: Base Firmware Version BSV:x